CHAPTER 2
The SIM 3 Hardware
2.2. SIM-3088 LINE SWITCHER
When larger systems or more sophisticated needs are involved, the SIM-3088 line switcher is
the perfect solution for measuring multiple points in the signal chain, as individual branches.
The single rack, multiple-configuration 16-channel line-level switcher allows immediate
access to the key measurement points in a multi-channel sound system..
Once patched into the system, measuring any point in the system can be accomplished
without ever needing to touch a patch cable, since processor inputs and outputs are
software-selected through the switchers. The compact 1U rack mount profile makes it
practical to place the switchers exactly where you need them — whether at front of house, a
remote equipment room, or other location. Multiple line switchers can be daisy-chained.
2.2.1. Front Panel
Mute
Enabled
Safe
Data
Bus Pwr
Addr
Bus Sele ct
Mute
9
10
11
12
13
14
15
16
5
6
7
8
1
2
3
4
PROC ESSOR
Bus Sele ct
Mute
CONS OLE / P ROCE SSOR
Bus Sele ct
Mute
CONS OLE / P ROCE SSOR

0


























2.2.1.1. Address Switch
Each SIM-3088 switcher has unique connections into the sound system under test. Therefore
each must have a unique network address, which allows the SIM-3022 to manage the
measured signals.
Up to 10 addresses can be selected (0 - 9). The address can be changed using a small
screwdriver or a pen.
Data
Bus Pwr
Addr
wit
0
decrement address by 1
increment address by 1
CAUTION: Line switchers sharing the same address will fail to pass signal to
any bus in the system. The SIM 3 screen will show a switcher address conflict
in the Status bar, which normally is green and says “Acquiring Data”, by changing to
yellow and saying “Switcher Conflict.” When the Speakers tab is set to the switcher
that has a conflict, its status bar also turns yellow and says “Address Conflict.”