CHAPTER 8
SIM 3 Menus
8.6. PROCEDURE
The Procedures are step-by-step methods to perform certain measurements using SIM 3.
The dialog box will remain on the screen, providing instructions while the various settings are
changed to perform the measurement.
Figure 8.13. The Procedure menu dropdown
8.6.1. Mic SPL Calibration
This procedure is used to determine the sensitivity of a measurement microphone, using an
external calibrator.
NOTE: The Calibrate Microphone button on the SIM 3 screen in the
Spectrum measurements automates much of this process.
8.6.2. Check Noise
This procedure is used to determine the noise floor of the various devices in the signal
processing path.
8.6.3. Check Max Output
This procedure is used to determine the maximum output level before clipping for all of the
measurement points in the branches.
8.6.4. Verify Polarity
This procedure is used to determine the polarity of each of the measurement points,
including the various electronics components in the processor path, and the individual
loudspeakers within the system.