Meyer Sound SIM 3 User's Guide Page 143

  • Download
  • Add to my manuals
  • Print
  • Page
    / 232
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 142
137
CHAPTER 7
Using SIM 3
7.4.2. Storing Measurements
To store a measurement, press the Store button in the Selector tab or click Data > Store
DataGroup. The Store DataGroup dialog appears. Alternately, press F5 for QuickStore,
discussed below.
The following data fields will be stored as one DataGroup:
# — The branch number assigned by SIM 3.
Branch — The branch name.
Group — The group number for the data. The group number is the unique numeric
identifier for one row of data.
Mode — The SIM 3 Mode you are currently in.
Name — A descriptive name for the data.
Procedure — The name of the Procedure (not currently active).
Console — The name of the console channel.
Processor — The name of the processor channel.
Microphone — The name of the microphone channel.
Saved — A date and time stamp of when the data was saved.
Notepad — Any additional notes or comments you would like to enter to save for later
reference.
Delay — The delay time for each channel.
Offset — The offset in dB for each channel.
Averages — The number of averages used for each measurement point.
Amplitude Threshold — The amplitude threshold for each channel.
Coherence Threshold — The coherence for each channel.
Speaker On/Off Info — The loudspeakers that were on in the particular measurement;
the others were muted.