CHAPTER 7
Using SIM 3
7.13.8.1. Set System Equalization — Processor — Live
1. Select the Frequency Response measurement. Select the Group view. Go to the bottom
center of the SIM 3 screen and click on the Values tab.
2. Equalization can be done with live data alone or with reference to one or more stored
traces. To recall a trace from memory, select Data > Recall DataGroup. Click on the
name of the data group to be the reference. Select the Memory row (A through D) in
which to place it, and press Recall.
3. Use the Trace Offset keys to move both the live and the recalled Room/Speaker traces
up/down until they are centered over the Processor trace.
4. Adjust the equalizer bands until the Processor trace has created a complement to the
Room/Speaker traces and the desired Result trace has been achieved. Select View >
Processor Inverted if you desire to match the EQ curve on the screen to the traces (the
processor line will be green in this view).
5. Store this measurement by selecting Data > Store DataGroup. Record the various
equalizer values used to produce the desired equalization in the Notes field.
7.13.8.2. Set System Equalization — Processor — Silent EQ
1. Select the Frequency Response measurement. Select the Group view. Go to the
bottom center of the SIM 3 screen and click on the Values tab. Equalization is done
with reference to one or more stored traces. The Speakers are muted (click All Off at the
bottom of the Speakers tab on the right side of the SIM 3 screen) and the live Processor
data is viewed with the stored Room/Speaker data.
2. Obtain a reference trace from memory. Select Data > Recall DataGroup. Click on the
name of the data group that you want to equalize. Select the Memory row (A through D)
in which to place it, and press Recall.
3. Use the Trace Offset keys to move the recalled Room/Speaker trace up/down until it is
centered over the Processor trace.
4. Adjust the equalizer bands until the Processor trace has created a complement to the
Room/Speaker traces. Select View > Processor Inverted if you desire to match the EQ
curve on the screen to the traces (the processor line will be green in this view).
5. Store this measurement by selecting Data > Store DataGroup. Record the various
equalizer values used to produce the desired equalization in the Notes field.