Meyer Sound 500-HP Operations Instructions

Browse online or download Operations Instructions for Subwoofers Meyer Sound 500-HP. Meyer Sound 500-HP Operating instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Keep these important operating instructions.
Check www.meyersound.com for updates.
OPERATING INSTRUCTIONS
500-HP Compact High-Power Subwoofer
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - OPERATING INSTRUCTIONS

Keep these important operating instructions. Check www.meyersound.com for updates.OPERATING INSTRUCTIONS500-HP Compact High-Power Subwoofer

Page 2

CHAPTER 1: INTRODUCTION10

Page 3 - IMPORTANT SAFETY INSTRUCTIONS

11CHAPTER 2: POWER REQUIREMENTSThe 500-HP subwoofer combines advanced loudspeaker technology with equally advanced power capabilities. Understanding p

Page 4 - SAFETY SUMMARY

CHAPTER 2: POWER REQUIREMENTS12The AC Loop Output Connector (Gray)The gray AC Loop Output connector allows multiple 500-HP subwoofers to be looped and

Page 5 - CONTENTS

500-HP OPERATING INSTRUCTIONS13CAUTION: The power source for the 500-HP should always operate within the required volt-age range, at least a few volts

Page 6

CHAPTER 2: POWER REQUIREMENTS14NOTE: For best performance, the AC cable voltage drop should not exceed 10 V, or 10 percent at 115 V and 5 percent at 2

Page 7

15CHAPTER 3: AMPLIFICATION AND AUDIOThe low-frequency drivers in the 500-HP are powered by a two-channel proprietary Meyer Sound amplifier with MOSFET

Page 8

CHAPTER 3: AMPLIFICATION AND AUDIO16Loop Output ConnectorThe male XLR Loop connector allows multiple 500-HP sub-woofers to be looped from a single aud

Page 9

500-HP OPERATING INSTRUCTIONS17On/Temp LEDWhen the 500-HP is powered on, its On/Temp LED turns green. If the temperature of the heatsink reaches 85° C

Page 10 - CHAPTER 1: INTRODUCTION

CHAPTER 3: AMPLIFICATION AND AUDIO18AMPLIFIER COOLING SYSTEMThe amplifier for the 500-HP uses natural convection for cooling at low to moderate audio

Page 11 - CHAPTER 2: POWER REQUIREMENTS

19CHAPTER 4: INTEGRATING 500-HP SUBWOOFERSINTEGRATING 500-HP SUBWOOFERS WITH MEYER SOUND LOUDSPEAKER SYSTEMSIt is often necessary to augment mid-high

Page 12 - 500-HP VOLTAGE REQUIREMENTS

iiDECLARATION OF CONFORMITY ACCORDING TO ISO/IEC GUIDE 22 AND EN 45014Manufacturer’s Name:Meyer Sound Laboratories Inc.Manufacturer’s Address:2832 San

Page 13 - 500-HP CURRENT REQUIREMENTS

CHAPTER 4: INTEGRATING 500-HP SUBWOOFERS20Placement for 500-HP SubwoofersAn important factor governing subwoofer response is their placement relative

Page 14 - ELECTRICAL SAFETY ISSUES

500-HP OPERATING INSTRUCTIONS21measurement system like Meyer Sound’s SIM 3 is rec-ommended to determine appropriate delay and polarity settings.DIGITA

Page 15 - AUDIO INPUT MODULES

CHAPTER 4: INTEGRATING 500-HP SUBWOOFERS22

Page 16 - Limit LED

23CHAPTER 5: QUICKFLY RIGGING500-HP subwoofers equipped with the optional MRF-500 rigging frame can be linked directly to the MG-M’elodie multipurpose

Page 17 - Input Module (Optional)

CHAPTER 5: QUICKFLY RIGGING24GuideALinks are easily set to one of three positions (A, B, or C) with accessible knobs. GuideALink labels indicate the p

Page 18 - AMPLIFIER COOLING SYSTEM

500-HP OPERATING INSTRUCTIONS25Groundstacking 500-HPs with M’elodiesA maximum of five M’elodies can be groundstacked above a single 500-HP. When groun

Page 19 - ■ System configuration

CHAPTER 5: QUICKFLY RIGGING26CAUTION: When securing GuideALinks to the MG-M’elodie grid, make sure to use the quick-release pins with the red or blue

Page 20 - WITH LOUDSPEAKERS

500-HP OPERATING INSTRUCTIONS27Adjusting the Angle for MG-M’elodie Grid and 500-HP ConfigurationsWhen the MG-M’elodie’s front and rear GuideALinks are

Page 21 - SUBWOOFERS

CHAPTER 5: QUICKFLY RIGGING28more information, see “MG-M’elodie Grid Load Rat-ings” on page 26 and “500-HP Load Ratings” on page 30.500-HP with Flown

Page 22

500-HP OPERATING INSTRUCTIONS29500-HPs with Flown M’elodies500-HPs can be flown within M’elodie arrays to supplement and extend low-frequency headroom

Page 23 - CHAPTER 5: QUICKFLY RIGGING

iiiSYMBOLS USEDThese symbols indicate important safety or operating features in this booklet and on the chassis:IMPORTANT SAFETY INSTRUCTIONS1. Read t

Page 24 - GROUNDSTACKING 500-HPS

CHAPTER 5: QUICKFLY RIGGING30500-HP Load RatingsTable 9 lists the maximum number of M’elodies that can be safely suspended from a 500-HP. For MG-M’elo

Page 25 - THE MG-M’ELODIE GRID

500-HP OPERATING INSTRUCTIONS31Safety Guidelines for Using the MCF-500 Caster Frame Do not stack more than three 500-HPs. When transporting stacks,

Page 26 - MG-M’elodie Grid Load Ratings

CHAPTER 5: QUICKFLY RIGGING32

Page 27 - 500-HP Configurations

33CHAPTER 6: THE RMS REMOTE MONITORING SYSTEMAn optional RMS remote monitoring system module can be installed in the 500-HP, allowing it to be connect

Page 28 - 500-HP with Flown 500-HPs

CHAPTER 6: THE RMS REMOTE MONITORING SYSTEM34The RMS software displays all loudspeakers on the network in a panel with icons, Meter views, and Text vi

Page 29 - 500-HPs with Flown M’elodies

500-HP OPERATING INSTRUCTIONS35Reset ButtonPressing the Reset button causes the RMS module’s firm-ware to reboot; this will not affect whether the lou

Page 30 - THE MCF-500 CASTER FRAME

CHAPTER 6: THE RMS REMOTE MONITORING SYSTEM36

Page 31 - POLE-MOUNT RECEPTACLE

37CHAPTER 7: SYSTEM DESIGN AND INTEGRATION TOOLSMeyer Sound offers two comprehensive tools to assist with the acoustical and functional requirements o

Page 32

CHAPTER 7: SYSTEM DESIGN AND INTEGRATION TOOLS38Using MAPP Online ProMAPP Online Pro is compatible with the following operating systems: Windows Lin

Page 33 - THE RMS SOFTWARE

39APPENDIX A: OPTIONAL VEAM MULTIPIN CONNECTORThe 500-HP subwoofer requires a grounded outlet. It is very important that the system be properly ground

Page 34 - Wink LED (Green)

ivSAFETY SUMMARYEnglish To reduce the risk of electric shock, dis-connect the loudspeaker from the AC mains before installing audio cable. Reconnect

Page 35 - RESETTING THE RMS MODULE

APPENDIX A: OPTIONAL VEAM MULTIPIN CONNECTOR40

Page 36

41APPENDIX B: OPTIONAL RAIN HOODWeather-protected versions of the 500-HP subwoofer are available with rain hood kits that safeguard the subwoofer’s el

Page 37 - MAPP Online Pro Applications

APPENDIX B: OPTIONAL RAIN HOOD423. Attach the user panel rain hood assembly to the user panel, slipping it under the flange at the top of the panel an

Page 38 - SIM 3 Applications

43APPENDIX C: SPECIFICATIONS500-HP COMPACT HIGH-POWER SUBWOOFER SPECIFICATIONS500-HP SpecificationsACOUSTICALOperating Frequency Range35 Hz – 140 HzNo

Page 39

APPENDIX C: SPECIFICATIONS44AMPLIFIERType Two-channel complementary MOSFET output stages (class AB/H)Output Power 1800 W total (2 x 900 W)Note: Wattag

Page 40

500-HP OPERATING INSTRUCTIONS45500-HP Dimensions15.45 [392 mm]18.23 [463 mm]18.00 [457 mm]26.55 [674 mm]22.50 [572 mm]22.18 [563 mm]Ø1.52 [Ø39 mm]8.50

Page 41

APPENDIX C: SPECIFICATIONS46MCF-500 CASTER FRAME SPECIFICATIONSMCF-500 SpecificationsPHYSICALMaterials and ComponentsPremium birch plywood base with

Page 43 - APPENDIX C: SPECIFICATIONS

Meyer Sound Laboratories Inc. 2832 San Pablo Avenue Berkeley, CA 94702www.meyersound.com T: +1 510 486.1166 F: +1 510 486.835© 2009Meyer Sound. All ri

Page 44

vCONTENTSChapter 1: Introduction 7How to Use This Manual 7Introducing the 500-HP Subwoofer 7Chapter 2: Power Requirements 11AC Power Distribution 11Th

Page 46

7CHAPTER 1: INTRODUCTIONHOW TO USE THIS MANUALMake sure to read these operating instructions in their entirety before configuring a loudspeaker system

Page 47

CHAPTER 1: INTRODUCTION8allows the subwoofer to be easily paired with UltraSeries™ loudspeakers. Also included with all 500-HPs are durable plastic bo

Page 48 - 05.187.045.01 A

500-HP OPERATING INSTRUCTIONS9500-HP Groundstacked with M’elodiesMG-M’elodie Grid with 500-HP and M’elodie Array

Comments to this Manuals